E160 Fault on Baxi or Potterton Boiler? Fix it fast with our handy guide!
Learn what an E160 fault code means, how to troubleshoot it, and when to call a professional.
TLDR: You need a qualified gas-safe engineer to replace the fan and repair any other faults.
What is a Baxi E160 fault code?
An E160 on a Baxi or Potterton boiler means the fan is not working. It can normally be reset but will go back the same fault.
Why is my fan not running?
The fan motor has failed.
All moving parts will eventually fail. Most will last for a very long time but some will fail earlier than expected. The fan is designed to last for at least the period of the warranty. Most are expected to last much longer.
The internal control board in the fan has failed.
The electronic components on the fan are expected to last a long time but some will fail earlier. If the fan has been in damp conditions it life can be shorter. This can be caused by leaks in the boiler case. Or if the boiler has been turned off for a long periods.
The sensors on the fan can’t detect how fast the fan is running.
Modern boilers run the fan at different speeds to control the heat output of the boiler. To accurately control the heat output the boiler needs to know how fast the fan is turning. If the boiler doesn’t know how fast the fan is running then it can’t work safely. If the boiler isn’t sure it’s safe it displays the E160 fault code and turns off.
E160 because the wiring to the fan is damaged.
The main cause of the wiring being damaged are if there are water leaks on the connectors. Heat and fumes leaking from the combustion chamber, rough treatment when working on the boiler. I’ve even seen mice chewing through the wires. All the wiring can be checked using a multi meter. There should be continuity from one end to the other on all the individual wires that make up the cable.
The main boiler PCB isn’t sending the correct power and signals to the fan.
An engineer can check this by looking for the correct voltages at the connectors on the PCB. The voltages are available in the boiler instruction manual. When no power is sent to the fan it won’t turn. The main PCB will recognise that the speed is wrong and show a fault.
Modern boilers have variable speed fans which work with DC voltage. This makes them more susceptible to damp conditions and spikes in the supply.
How do I know the fan is faulty?
The simple answer to this is that the boiler will tell you. E160 on a Baxi or Potterton boiler is a very reliable fault code. The main control board is constantly checking the speed of the fan and comparing it to an expected reading. If a reading is incorrect it will display an E160 fault code.
When the boiler is turned on there are two main sounds.
- The sound of the pump moving water around the boiler.
- The sound of air being blown through the boiler by the fan.
If there is a demand from the central heating (timer on and thermostat turned up) the radiator light will turn on by the number display. The water pump will start to run then after a short delay, the fan will start to run.
The noise coming from the fan should mostly be the sound of the air moving and the motor turning. Any grating or knocking sounds from the boiler are a sign that the fan is worn or damaged.


What should I do if I get an E160 fault?
Unfortunately changing a fan is not a DIY under any circumstances so a gas safe registered engineer is required.
Why can I not change the fan myself for an E160 fault?
Changing a fan is not a DIY job. This is why:
- The fan in a modern gas boiler carries unburnt gas into the combustion chamber before it is burnt. If the correct seals aren’t used this gas could leak causing a fire or an explosion.
- The fan in a modern gas boiler carefully measures the amount of gas being introduced into the boiler. After the fan is changed the boiler has to be set up. The engineer needs the correct testing equipment to prove it is safe. Changing the fan without proper testing is very dangerous and should never be done.
For advice on other fault codes click here.
If you found this confusing:
If you found this confusing. Please let us know in the comments section so we can clear things up for you. We love feedback and we are trying to make the best possible website. If you don’t understand then others don’t as well.
If you found this useful:
If you found this useful maybe check some of our other pages.
- My radiators are too hot
- Vaillant F28 fault
- Common causes of a Vaillant F75 fault
- Boiler pressure dropping
- E160 Fault on Baxi or Potterton Boiler
- Expansion vessel problems
- F1 low pressure fault on an Ideal Logic boiler
- Filling loop left open
- Do I need a powerflush?
- E50 fault
- Hello deary